↑ برای مشاهده محصولات بیشتر در این زمینه به کاتالوگ اصلی فوق مراجعه نمایید ↑
Deltabar Pressure
Deltabar PMD55B – differential pressure transmitter
Smart transmitter with metal membrane for differential pressure monitoring in liquids and gases
Specs at a glance
Accuracy
Standard:
up to 0.075 %
Platinum:
up to 0.055 %
Process temperature
-40°C…+110°C (-40°F…+230°F)
Pressure measuring range
30 mbar…. 40 bar (0.45 psi… 600 psi)
Main wetted parts
316L, AlloyC
Material process membrane
316L, AlloyC
Measuring cell
30 mbar…40 bar
(0.45 psi…600 psi)
Deltabar PMD75B – differential pressure transmitter
Smart pressure transmitter which detects process anomalies like plugged impulse lines
Specs at a glance
Accuracy
Standard:
up to 0.05 %
Platinum:
up to 0.035 %
Process temperature
-40°C…+110°C
(-40°F…+230°F)
Pressure measuring range
10 mbar…250 bar
(0.15 psi…3750 psi)
Main wetted parts
316L, AlloyC,
Tantal, Monel,
Gold
Material process membrane
316L, AlloyC,
Tantal,
Monel,
Gold
Measuring cell
10 mbar…250 bar
(0.15 psi…3750 psi)
Cerabar Pressure
Cerabar PMP51B – pressure transmitter
Smart pressure transmitter with metal membrane for highly accurate measurement of liquids and gases
Specs at a glance
Accuracy
Standard:
up to 0.075 %
Platinum
up to 0.055 %
Process temperature
Standard:
-40°C…+125°C
(-40°F…+257°F)
Diaphragm seal:
-40°C…+400°C
(-40°F…+752°F)
Pressure measuring range
400 mbar… 400 bar
(6psi…6,000psi)
Main wetted parts
316L, AlloyC,
Tantal, Monel,
PTFE
Material process membrane
316L, AlloyC,
Tantal, Monel,
PTFE
Measuring cell
400 mbar…400 bar
(6psi…6,000psi)
Cerabar PMP71B – pressure transmitter
Smart pressure transmitter – its health can be verified without process interruption
Specs at a glance
Accuracy
Standard:
up to 0.05 %
Platinum:
up to 0.025 %
Process temperature
Standard:
-40°C…+125°C
(-40°F…+257°F)
Diaphragm seal:
-40°C…+400°C
(-40°F…+752°F)
Pressure measuring range
400 mbar…700 bar
(1.5 psi…10,500 psi)
Main wetted parts
316L, AlloyC,
Tantal, Monel,
PTFE, Gold
Material process membrane
316L, AlloyC,
Tantal, Monel,
PTFE,
Gold
Measuring cell
400 mbar…700 bar
(6 psi…10,500 psi)
Electronic Deltabar Pressure
Electronic differential pressure
Deltabar FMD71
Electronic differential pressure system utilizing two ceramic sensor modules and one transmitter
Specs at a glance
Accuracy
0.075% of individual sensor,
“PLATINUM” 0.05% of individual sensor
Process temperature
–25…+150°C
(–13…+302°F)
Pressure measuring range
100mbar…40bar
(1.5psi…600psi)
Process pressure / max. overpressure limit
60 bar (900 psi)
Material process membrane
Ceramic
316L, AlloyC
Measuring cell
100 mbar…40 bar
(1.5 psi…600 psi)
Electronic differential pressure
Deltabar FMD72
Electronic differential pressure system utilizing two metal sensor modules and one transmitter
Specs at a glance
Accuracy
0.075% of individual sensor,
“PLATINUM” 0.05% of individual sensor
Process temperature
–40…+125°C
(–40 … +257°F)
Pressure measuring range
400 mbar…10 bar
(6 psi…150 psi)
Process pressure / max. overpressure limit
160 bar (2400 psi)
Main wetted parts
316L, Alloy C
Material process membrane
316L, AlloyC,
Measuring cell
400 mbar…10 bar
(6 psi…150psi)
Deltapilot Pressure
Hydrostatic Level measurement
Deltapilot FMB50
Compact pressure sensor with the Contite measuring cell for hydrostatic level measurement
Specs at a glance
Accuracy
Standard 0.2%
Optional 0.1%
Process temperature
-10°C…100°C
(14°F…212°F)
Pressure measuring range
100 mbar…10 bar
(1.5 psi…150 psi)
Process pressure / max. overpressure limit
40 bar (600 psi)
Main wetted parts
Alloy C
316L
optional coating AuPt
Max. measurement distance
100m (328ft) H2O
Material process membrane
316L, AlloyC
Gold-Rhodium
Measuring cell
100 mbar…10 bar
(1.5 psi…150 psi)
Hydrostatic Level measurement
Deltapilot FMB51
Pressure sensor with the Contite measuring cell for hydrostatic level measurement
Specs at a glance
Accuracy
Standard 0.2%
Optional 0.1%
Process temperature
-10°C…85°C
(14°F…212°F)
Pressure measuring range
100 mbar…10 bar
(1.5 psi…150 psi)
Process pressure / max. overpressure limit
40 bar (600 psi)
Main wetted parts
Alloy C
316L
optional coating AuPt
Max. measurement distance
100m (328ft) H2O
Material process membrane
316L, AlloyC
Gold-Rhodium
Measuring cell
100 mbar…10 bar
(1.5 psi…150 psi)
Ceraphant Pressure
Absolute and gauge pressure
Ceraphant PTC31B
Cost-effective pressure switch with oil-free ceramic sensor for measurement in gases or liquids
Specs at a glance
Measuring cell
+100 mbar….+40 bar
(+1.5 psi….600 psi)
Absolute and gauge pressure
Ceraphant PTP31B
Cost-effective pressure switch with welded metal sensor for measurement in gases, steams or liquids
Specs at a glance
Measuring cell
+400 mbar….+400 bar
(+6 psi…+6000 psi)
Hydrostatic Pressure
Hydrostatic Level measurement
Waterpilot FMX11
Simple and reliable level probe for freshwater applications
Specs at a glance
Accuracy
pn ≥ 400mbar: 0.35 %
pn < 400mbar: 0.50 %
Process temperature
-10°C…+70°C
(+14°F…+158°F)
Pressure measuring range
200 mbar…2 bar
(3 psi…29 psi)
Process pressure / max. overpressure limit
10 bar (145 psi)
Main wetted parts
316L
Max. measurement distance
20 m H2O
(66 ft H2O)
Material process membrane
Metal
Measuring cell
200 mbar…2 bar
(3 psi…29 psi)
Hydrostatic Level measurement
Waterpilot FMX21
Reliable and robust level probe with ceramic measuring cell and HART
Specs at a glance
Accuracy
0.2%
0.1% (optional)
Process temperature
-10°C…70°C
(14°F…158°F)
Diameter 29 mm (1.14″): 0°C…50°C
(32°F…122°F)
Pressure measuring range
100 mbar…20 bar
(1.5 psi…300 psi)
Main wetted parts
Diameter 22 mm and 42 mm: Seal, 316L, Ceramic
Diameter 29 mm: Seal, PPS, Polyolefin, Ceramic
Extension cable: PE, PUR, FEP
Max. measurement distance
200 m H2O
(656 ft H2O)
Measuring cell
100mbar…20bar
(1.5psi…300psi)