Radar Level
Micropilot FMR60B – 80 GHz radar sensor
More simplicity for your application
Specs at a glance
Accuracy
+/-1 mm (0.04 in)
Process temperature
-40 … +200 °C (-40 … +392 °F)
Process pressure / max. overpressure limit
Vacuum…20 bar (290 psi)
Max. measurement distance
50 m (164 ft)
Main wetted parts
PVDF, PTFE or PEEK
Micropilot FMR62B – 80 GHz radar sensor
Smart Safety for your process
Specs at a glance
Accuracy
+/-1 mm (0.04 in)
Process temperature
-196 … +450 °C (-321 … +842 °F)
Process pressure / max. overpressure limit
Vacuum…160 bar (2320 psi)
Max. measurement distance
80 m (262 ft)
Main wetted parts
316L or PTFE (clad 316L flanges)
Guided radar measurement
Time-of-Flight Levelflex FMP50
For all basic level applications in liquids
Specs at a glance
Accuracy
Rod probe: +/- 2 mm (0.08 in)
Rope probe: +/- 2 mm (0.08 in)
Process temperature
-20…+80 °C
(-4…+176 °F)
Process pressure / max. overpressure limit
Vacuum…6 bar,
(Vacuum…87 psi)
Max. measurement distance
Rod: 4 m (13 ft) Min DK>1.6
Rope: 12 m (40 ft) Min DK>1.6
Main wetted parts
Rod probe: 316L, PPS, Viton
Rope probe: 316, PPS, Viton
Capacitance Point Level
Capacitance Point level detection
Liquipoint FTW23
Cost effective point level switch for water-based liquids
Specs at a glance
Process temperature
Standard:
-20 … 100°C
Cleaning:
-20 … 135°C for 1h
-4 … 275F for 1h
Process pressure / max. overpressure limit
Vacuum … 16 bar
Vacuum ….232 psi
Capacitance Point level detection
Solicap FTI77
Point level detection for bulk solids, especially for high temperatures and strong mechanical loads
Specs at a glance
Process temperature
-50°C … 400°C
(-58°F … 752°F)
Process pressure / max. overpressure limit
Vacuum … 10 bar
(Vacuum … 145 psi)
Liquiphant Level
Liquiphant FTL51B – digital, simple and safe
Point level switch for all liquid media
Specs at a glance
Process temperature
-50 °C…+150 °C
(-58 °F…+302 °F)
Process pressure / max. overpressure limit
Vacuum…100 bar
Vacuum…1450 psi
Min. density of medium
0.5 g/cm³
(0.4 g/cm³ optional)
Liquiphant FTL62 – the specialist for aggressive media
A level switch for aggressive and pumpable liquids
Specs at a glance
Process temperature
-50 °C…+150 °C
(-58 °F…+302 °F)
Process pressure / max. overpressure limit
Vacuum…40 bar
Vacuum…580 psi
Min. density of medium
0.5 g/cm³
(0.4 g/cm³ optional)
Ultrasonic Measurement Level
Ultrasonic measurement
Time-of-Flight Prosonic FDU90
Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 3m)
Specs at a glance
Process temperature
-40 °C … 80 °C
(-40 °F … 176 °F)
Process pressure / max. overpressure limit
0.7 bar … 4 bar abs
(10 psi … 58 psi)
Max. measurement distance
Liquids: 3 m (9.8 ft),
Solids: 1.2 m (3.9 ft)
Accuracy
+/- 2mm + 0.17% of measured distance
Main wetted parts
PVDF (IP68 / NEMA6P)
Ultrasonic measurement
Time-of-Flight Prosonic FDU91
Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 10m)
Specs at a glance
Process temperature
-40 °C … 80 °C
(-40 °F … 176 °F)
Process pressure / max. overpressure limit
0.7 bar … 4 bar abs
(10 psi … 58 psi)
Max. measurement distance
Liquids: 10 m (33 ft),
Solids: 5 m (16 ft)
Accuracy
+/- 2 mm + 0.17% of measured distance
Main wetted parts
PVDF (fully welded IP68 / NEMA6P)
Radiometric Level
Radiometric level and density measurement
Gammapilot FMG50
Compact transmitter for point level detection, continuous level, interface and density measurement
Specs at a glance
Process temperature
Any
Process pressure / max. overpressure limit
Any
Max. measurement distance
Unlimited measuring range,
Cascade
Accuracy
+/-1%
Main wetted parts
Non-contact
Radiometric level and density measurement
Gamma Source FSG60
Gamma radiation source (137Cs) for radiometric level, point level, density and interface measurement
Specs at a glance
Process pressure / max. overpressure limit
Any
Vibronic Point Level
Vibronic Point level detection
Liquiphant FTL31
Point level switch for liquids in compact design with stainless steel housing
Specs at a glance
Process temperature
-40 °C … 150 °C
(-40 °F … 302 °F)
Process pressure / max. overpressure limit
Vacuum … 40 bar
(Vacuum … 580 psi)
Min. density of medium
>0,7g/cm³
(>0,5g/cm³ optional)
Vibronic Point level detection
Liquiphant FTL33
Point level switch for liquids in compact hygienic design for the food industry
Specs at a glance
Process temperature
-40 °C … 150 °C
(-40 °F … 302 °F)
Process pressure / max. overpressure limit
Vacuum … 40 bar
(Vacuum … 580 psi)
Min. density of medium
>0,7g/cm³
(>0,5g/cm³ optional)