Micro Motion T150T Straight Tube Coriolis Meter, 1 1/2 Inch (DN40), Titanium Grade 9, 32 Ra Finish
A Titanium grade 9, single, straight-tube Coriolis flow and density meter with 32 Ra surface finish that is drainable with a plug-resistant flow path.
Specifications
Mass flow accuracy (Liquid)±0.15% of rate
Mass flow repeatability (Liquid)±0.05% of rate
Volume flow accuracy (Liquid)±0.25% of rate
Volume flow repeatability (Liquid)±0.05% of rate
Mass flow accuracy (Gas)±0.50% of rate
Mass flow repeatability (Gas)±0.05% of rate
Density accuracy (Liquid)±0.002 g/cm3 (±2.0 kg/m3)
Density repeatability (Liquid)±0.0005 g/cm3 (±0.5 kg/m3)
Temperature accuracy±1 °C ±0.5% of reading
Sensor maximum working pressure1,450 psig (100 barg)
Meter approvals, calibrations, and certifications
•UL
•CSA
•ATEX
•ASME
•3-A
•USDA
•EHEDG
Micro Motion 5700 Field-Mount Transmitter
Delivering the best in measurement technology and unparalleled support, the 5700 transmitter’s intuitive design ensures measurement confidence, valuable process insight and productivity through simplified solutions. Data historian feature captures rich information about process events, fluid quality, and measurement stability – over long and short periods of time. Zero Verification tool provides confidence in the meter zero and analyzes process conditions to indicate potential issues for re-zeroing.
Specifications
Local display
Graphical backlit display
Four-button optical controls
Flowmeter-status LED
Supports English, German, French, Spanish, Portuguese, Russian, Chinese, and Japanese languages.
Power
Self-switching AC/DC input, automatically recognizes supply voltage
85 to 2405 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum
18 to 100 VDC, 6 watts typical, 11 watts maximum
Complies with Low Voltage Directive 2006/95/EC per IEC 61010-1 Ed. 3.0 2010-06; Overvoltage Category II, Pollution Degree 2
Universal Service PortUniversal Service Port design allows for connection and data transfer using standard, readily available equipment.
Configurable I/O versionUp to 5 licensable channels with the following possible configurations:
1 to 3 4-20 mA outputs
1 to 3 Pulse outputs
1 to 3 Discrete outputs
1 to 2 Discrete inputs
1 mA input
1 Modbus/RS-485
Channel A: mA/HART
Channel B: mA/FO/DO
Channel C: mA/FO/DO/DI
Channel D: mA-input/FO/DO/DI
Channel E: Modbus RS-485
Communication ProtocolWirelessHART
WirelessHART available with the 775 Smart Wireless THUM adapter.
FOUNDATION Fieldbus version
FOUNDATION Fieldbus channel
mA output
Pulse output
PROFIBUS-PA version
PROFIBUS-PA channel
mA IS output
Pulse IS output
Wi-Fi Display Option:Wi-Fi display option enables point-to-point wireless communication in order to configure and characterize the meter, download historical files, and run Smart Meter Verification for troubleshooting purposes. Available for the 5700 Config I/O version only.
Intrinsically Safe versionUp to 4 licensable IS channels with the following configurations:
Channel A: mA/HART
Channel B: mA
Channel C: mA/FO
Channel D: FO
Channel E: Not Used
SIL Certified Device Available – Uses an internal readback loop to verify the milliamp output
Ethernet version
Dual Ethernet ports supporting EtherNet/IP, Modbus TCP, and PROFINET all in one device
Additional channel included configurable to mA output, pulse output, discrete output, or discrete input
Pre-installed M12 quick connections available as an option
Mounting options
Field-mount aluminum and stainless steel housing options
Integrally mounted to a Micro Motion ELITE (CMFS), F-series, H-series, R-series, or T-series Coriolis sensor (aluminum only)
Remotely mounted to any 4-wire or 9-wire Micro Motion ELITE®, F-series, H-series, R-series, or T-series Coriolis sensor (aluminum and stainless steel versions)
Application types
Smart Meter Verification Professional
Discrete batch control
Petroleum measurement and API correction option
Concentration measurement
Advanced Phase Measurement for two phase flow remediation
Piecewise Linearization for Gas Applications
Certificates/ApprovalsHazardous approvals
Class I, Div. 1
Class I, Div. 2
Zone 1
Zone 2
SIL/SIS Certification
5700 Config I/O and Intrinsically Safe versions are certified for SIL2 single use and SIL3 multiple use safety applications per IEC 61508. Please refer to the Safety Manual in the document manuals and guides section.
Coriolis Spare Parts
ProLink III Configuration & Service Tool for Micro Motion and Rosemount Flow Meters
Featuring an intuitive interface, the ProLink III Microsoft Windows-based software application empowers you to easily access all the information you may need to configure, assess and manage your Micro Motion and Rosemount flow meters.
Specifications
Operating SystemWindows 10, Windows 8, Windows 7, Windows Vista (with Service Pack 1 or later). Note: Windows XP (with ServicePack 3 or later) is compatible with ProLink III version 4.3 or earlier
iOS and Android tablet version available on iOS and Google Play stores. The tablet version is only compatible with the 5700 Config I/O transmitter with the Wi-Fi display option.
Hardware Requirements• Processor-Pentium 4 or higher (1 GHz min, 2 GHz higher recommended)
• RAM- 1 GB min, 2 GB higher recommended
• Disk space-1 GB for 32-bit(x86) Windows, 2 GB for 64-bit (x64)Windows
• CD-ROM drive-4 or faster
Graphics RequirementsVideo-24-bit color graphics or higher, 1024 x 768 display minimum, 1280 x 800 or higher widescreen format preferred
Communication ProtocolsProtocol (physical layer), HART (Bell 202, RS-485), Modbus (RS-485), Modbus (USB), Modbus TCP (Ethernet)
Coriolis Transmitters
Micro Motion 3500 Controller And Transmitter, Remote Rack/Panel-Mount
With combined Coriolis transmitter functions and PLC capabilities, the Series 3000 is built for industry-focused solutions, including net oil computer, enhanced density, custody transfer and marine fuel bunkering solutions.
Specifications
Output variables
Mass & volume flow
Net product content / flow
Temperature
Density
Concentration
Local displayMulti-line LCD panel
Backlit LCD, 128 × 128 pixel, bit map
Adjustable contrast
Non-glare, chemical-resistant acrylic lens
Large push buttons with tactile feedback
Software-defined function keys
PowerAC option:
85 to 265 VAC
50/60 Hz, 30 VA
Complies with European low-voltage directive 2006/95/EC per IEC 61010-1, and Installation (Overvoltage) Category II, Pollution Degree 2DC option:
18 to 30 VDC
18 watts
typical, 25 watts maximum
Input/output signals
TTwo active 4–20 mA
Three discrete outputs
One 2-wire frequency output
One 2-wire frequency input
Two discrete momentary inputs
HART/WirelessHARTBell 202 signal is superimposed on the primary milliamp output
Mounting optionsControl-room DIN rail or panel-mount
Application types
Batch controller
Custody transfer
Two-phase flow/entrained gas
Meter verification
Hazardous approvalsSuitable for non-hazardous areas only
Micro Motion 9739MVD Field And Truck Mount Multivariable Transmitter
The 9739 MVD transmitter provides a versatile architecture for process control and custody transfer applications as well as a variety of I/O channels for application flexibility with a robust, field-mount design. Quantity 10 feet (3 meters) of 9-wire Teflon CFEPS cable is included.
Specifications
Output variablesMass & volume flow
Temperature
Density
Pressure
Concentration
API average density
Local displayStandard user interface with 2-line LCD panel
Two optical switches for local operation
Two clips for service port connections (requires removing transmitter housing cover)
Two clips for HART/Bell 202 connections (requires removing transmitter housing cover)
HART security switch (requires removing transmitter housing cover)
Glass lens
CommunicationBell 202
RS-485
PowerSelf-switching AC/DC input, automatically recognizes supply voltage
85 to 250 VAC, 48 to 62 Hz, 10 watts typical, 15 watts maximum
12 to 30 VDC, 7 watts typical, 14 watts maximum
Complies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2
Input/output signalsNot intrinsically safe
Two active mA outputs, configurable to 4–20 mA or 0–20 mA
One active/passive frequency/pulse output
One active/passive discrete output
One active discrete input
One sensor frequency output
One sensor temperature output
One mA input
Mounting optionsRemotely mounted to any 9-wire Micro Motion Coriolis sensor.
Application typesContinuous process control
Custody transfer
Two-phase flow/entrained gas
Concentration measurement
Petroleum measurement
Hazardous approvalsUL and CSA C-US: Without display
Transmitter:
Class I, Div. 1 , Groups C and D
Class II, Div. 1, Groups E, F, and G explosion proof when installed with approved conduit seals or Class I, Div. 2, Groups A, B, C, and D
Outputs:
Class I, Div. 2, Groups A, B, C and D with nonincendive sensor outputs
Class 1, Div. 1, Groups C and D and Class II, Div. 1, Groups E, F, and G with instrinsically safe sensor outputs
UL and CSA C-US: With display
Transmitter:
Class I, Div. 1 , Groups A, B, C, and D
Outputs:
Class I, Div. 2, Groups A, B, C and D with nonincendive sensor outputs
Class 1, Div. 1, Groups C and D and Class II, Div. 1, Groups E, F, and G with instrinsically safe sensor outputs
ATEX: Without display
Flame-proof transmitter: II 2 G Ex d[ib] IIB/IIC T6 Gb
Safe-area transmitter: II 2 G [Ex ib Gb] IIB/IIC
ATEX: With display
II (2)G [Ex ib Gb] IIB/IIC
Coriolis Accessories
ProLink III Configuration & Service Tool for Micro Motion and Rosemount Flow Meters
Featuring an intuitive interface, the ProLink III Microsoft Windows-based software application empowers you to easily access all the information you may need to configure, assess and manage your Micro Motion and Rosemount flow meters.
Specifications
Operating SystemWindows 10, Windows 8, Windows 7, Windows Vista (with Service Pack 1 or later). Note: Windows XP (with ServicePack 3 or later) is compatible with ProLink III version 4.3 or earlier
iOS and Android tablet version available on iOS and Google Play stores. The tablet version is only compatible with the 5700 Config I/O transmitter with the Wi-Fi display option.
Hardware Requirements• Processor-Pentium 4 or higher (1 GHz min, 2 GHz higher recommended)
• RAM- 1 GB min, 2 GB higher recommended
• Disk space-1 GB for 32-bit(x86) Windows, 2 GB for 64-bit (x64)Windows
• CD-ROM drive-4 or faster
Graphics RequirementsVideo-24-bit color graphics or higher, 1024 x 768 display minimum, 1280 x 800 or higher widescreen format preferred
Communication ProtocolsProtocol (physical layer), HART (Bell 202, RS-485), Modbus (RS-485), Modbus (USB), Modbus TCP (Ethernet)
Micro Motion ProcessViz
Micro Motion ProcessViz is a standalone software solution that takes Emerson’s Micro Motion 5700 or 4200 transmitter raw historian data and places it into an easy-to-use graphical format, offering a snapshot of the flow process. This software is a data visualization tool that eliminates the need for technicians to manipulate their data, thereby saving time.
Specifications
Operating SystemWindows 10, Windows 8, Windows 7, Windows Vista (with Service Pack 1 or later).
Hardware RequirementsProcessor-Pentium 4 or higher (1 GHz min, 2 GHz higher recommended)
RAM- 1 GB min, 2 GB higher recommended
Disk space-1 GB for 32-bit (x86) Windows, 2 GB for 64-bit (x64) Windows
CD-ROM drive-4 or faster
Graphics RequirementsVideo-24-bit color graphics or higher, 1024 x 768 display minimum, 1280 x 800 or higher widescreen format preferred
Differential Pressure Flow
Rosemount™ 3051SFA Annubar™ Flow Meter
The Rosemount 3051SFA Annubar Flow Meter is a no-equal solution with a patented, averaging pitot tube that delivers superior measurement accuracy over a wide flow range. This flow meter can measure multiple variables and is engineered with an integrated thermowell for temperature measurement. Its patented T-shaped sensor is capable of obtaining measurements via a single pipe penetration while maintaining a small profile in the pipe to reduce permanent pressure loss and increase energy savings.
Specifications
WarrantyUp to 15-year limited warranty
RangedownUp to 200:1 (14:1 flow turndown)
Measurement RangeUp to 1000 inH2O (2,48 bar) differential, Up to 3626 psia (250,00 bar) absolute, Up to 3626 psig (250,00 bar) gage
Line Size2 to 96 in. (50 to 2440 mm)
OutputDifferential pressure, static pressure, process temperature, scaled variable, mass flow, volumetric flow, energy flow
Communication Protocol4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus
Process Wetted Material316 SST, Alloy C-276
DiagnosticsBasic Diagnostics, Loop Integrity, Process Intelligence, Plugged Impulse Line
Certifications/ApprovalsSIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE, hazardous location, see full specs for complete list of certifications
Rosemount™ 2051 Differential Pressure Flow Transmitter
Designed to provide industry-standard performance, the Rosemount 2051 Differential Pressure Flow Transmitter offers dependable differential pressure (DP) flow measurements. For easy installation, this DP flow transmitter can be pre-assembled to various primary elements. This safety-certified transmitter also features a local operator interface (LOI) with easy-to-use menus and built-in configuration buttons for device commissioning without tools.
Specifications
WarrantyUp to 5-year limited warranty
RangedownUp To 100:1
Measurement RangeUp to 2000 psi (137,9 bar) differential
OutputDifferential pressure, scaled variable
Communication Protocol4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS®, 1-5 V Low Power HART®
Process Wetted Material316L SST, Alloy C-276, Tantalum
DiagnosticsBasic Diagnostics
Certifications/ApprovalsSIL 2/3 certified to IEC 61508 by an independent 3rd party, NSF, NACE®, hazardous location, see full specs for complete list of certifications
Magnetic
Magnetic Spare Parts
Magnetic Flow Meters
Magnetic Transmitters
Magnetic Accessories
Magnetic Spare Parts
Magnetic Flow Meters
Rosemount 8711 Wafer Magnetic Flow Meter Sensors
The flangeless design of the Rosemount 8711 Wafer Magnetic Flow Meter Sensor makes it an economical, compact and lightweight alternative to flanged magnetic flowmeters. Choose from a wide range of rugged liner and electrode material options compatible with virtually all applications, from highly corrosive liquids to fibrous slurries often considered difficult to measure with other devices. For easy installation, alignment spacer kits are provided with every 8711 meter to center the sensor in the process line.
Specifications
AccuracyUp to 0.15% of volumetric flow rate accuracy over 13:1 flow turndowns, 0.25% over 40:1 flow turndown
Line Sizes0.15-8 inch (4-200mm)
Liner MaterialsETFE, PTFE, and PFA
Electrode Materials316L Stainless Steel, Nickel Alloy, Platinum, Tantalum, Titanium
Consult factory for additional material options
Flange RatingsASME B16.5 Class 150-300
DIN PN 10-40
InterchangeabilityCompatible with all 8700 Series transmitters
Compatible with legacy transmitters: 8712D, 8712C, 8732C, 8742C
Rosemount 8705 Flanged Magnetic Flow Meter Sensors
Rosemount 8705 Flanged Magnetic Flow Meter Sensors provide long-lasting, reliable performance in even the most challenging applications. An all-welded construction provides a hermetic seal that protects against moisture and other contaminants. The sealed housing ensures maximum sensor reliability by protecting all internal components and wiring from even the most aggressive environments. A removable and replaceable terminal block enables easy repair in the field without the need to replace the entire meter.
Specifications
AccuracyUp to 0.15% of volumetric flow rate accuracy over 13:1 flow turndowns, 0.25% over 40:1 flow turndown
Line Sizes½-36 inch (15-900 mm)
Liner MaterialsPTFE, ETFE, PFA, Polyurethane, Neoprene, Linatex Natural Rubber
Electrode Materials316L Stainless Steel, Nickel Alloy, Platinum, Tantalum, Titanium
Flange RatingsASME B16.5 Class 150-2500DIN PN 10-40AS 2129 Table D and EAWWA C207 Table 3 Class D (30-36 inch only)
Submergence ProtectionIP68 (Recommended with sealed cable glands)
InterchangeabilityCompatible with all 8700 Series transmitters
Compatible with legacy transmitters: 8712D, 8712C, 8732C, 8742C
Magnetic Transmitters
Rosemount 8732E Field Mount Magnetic Flow Meter Transmitter
A dual-compartment transmitter housing provides isolation from the external environment. Advanced diagnostics and through-the-glass Local Operator Interface offer unparalleled process insight.
Rosemount 8732E Field Mount Magnetic Flow Meter Transmitter
A dual-compartment transmitter housing provides isolation from the external environment. Advanced diagnostics and through-the-glass Local Operator Interface offer unparalleled process insight.
Specifications
Sensor compatibilityCompatible with Rosemount 8705, 8711, and 8721sensors. Compatible with AC and DC powered sensors ofother manufacturers.
Transmitter coil drive current500mA
Flow rate rangeCapable of processing signals from fluids that are travelingbetween 0.04 and 39 ft/s (0.01 to 12 m/s) for both forwardand reverse flow in all sensor sizes. Full scale continuouslyadjustable between –39 and 39 ft/s (–12 to 12 m/s).
Conductivity limitsProcess liquid must have a conductivity of5 microSiemens/cm (5 micromhos/cm) or greater.
Power supply90 – 250VAC, 50/60Hz or 12 – 42VDC
Line power fuses90-250VAC systems
1A, 250V, I2t, 1.5 A2s Rating, Fast ActingBussman AGC-1, Littlefuse 31201.5HXP
12-42VDC systems
3 Amp, 250V, I2t, 14 A2s Rating, Fast ActingBel Fuse 3AG 3-R, Littelfuse 312003P, Schurter 0034.5135
Line power fuses15W maximum – DC
40VA maximum – AC
Switch-on currentAC: Maximum 35.7A (< 5ms) at 250VAC
DC: Maximum 42A (< 5ms) at 42VDC
Rosemount 8712E Magnetic Flow Meter Transmitter
Intuitive Local Operator Interface with dedicated keys enhance ease of use and enables instant access to all diagnostic information. Ideal for hazardous environments or difficult-to-reach locations.
Specifications
AccuracyUp to ±0.15% of volumetric flow rate accuracy over 13:1 flow turndowns, ±0.25% over 40:1 flow turndown.
Diagnostic1In Situ Meter Verification, Grounding ? Wiring Fault Detection, High Process Noise Detection, Tunable Empty Pipe Detection, Transmitter Fault Detection, Sensor Fault Detection
CompatibilityAll Rosemount manufactured Sensors: 8705, 8711, 8721, 8707
Universal capabilities allow E-Series transmitters to be compatible with AC and DC powered sensors from other manufacturers.
Power Supply90-250 VAC, 50-60 Hz or 12-42 VDC.
Power consumption15 W maximum – DC
40 VA maximum – AC
Enclosure Rating8712E: Type 4x, IP66
Magnetic Accessories
Rosemount 8785 Calibration Standard
The 8785 Calibration Standard is designed for use with the 8782 Slurry Transmitter. It can be used to provide an independent on-site validation of the 8782 calibration.
Specifications
Reference AccuracyUp to ±0.05% of volumetric flow rate accuracy at the 30 ft/s setting
Up to ±0.10% of volumetric flow rate accuracy at the 10 ft/s and 3 ft/s settings
ApprovalsOrdinary Location only
Compatibility8782 Slurry Transmitter
Weight10 lbs (4.5 kg)
Rosemount™ 8700M EtherNet/IP Modules
The Rosemount 8700EM EtherNet/IP™ Module for magnetic flow meters enables integration of industrial devices into the EtherNet network with no loss of functionality, control or reliability. The 8700EM EtherNet/IP™ Module offers network access to a powerful configuration and diagnostic interface for access to valuable multivariable data. Pre-configured and easy to use, the module delivers increased productivity and enhanced process insight for new or retrofit installations of the Rosemount 8732E transmitter and 8750W utility flow meter.
Specifications
HousingPlastic housing with snap-on connection to DIN rail
Protection classIP20
Dimensions4.72” × 2.95” × 1.06”
L×W×H (120mm × 75mm × 27mm)
Power Supply24 V ±10%
Power ConsumptionMaximum: 280 mA on 24 V
Typical: 100 mA
CompatibilityRosemount 8732E Field Mount
Transmitter with Rosemount 8705, 8711, and 8721 sensors; 8750W Utility Flow Meter System
CertificationsFully ODVA Certified
Vortex
Vortex Spare Parts
Vortex Flow Meters
Vortex Spare Parts
Vortex Flow Meters
Rosemount™ R306 In-Line Manifold
The Rosemount R306 In-Line Manifold assembles directly to in-line gauge or absolute pressure transmitters. Exclusively featured on the Rosemount R306 and R305 manifolds, the Pressure-Lock™ Valve offers simplified operation, enhanced reliability and increased operator safety. The R306 manifold is available with a 2-valve configuration for instrument isolation and drain/vent capabilities.
Specifications
Max. Operating Pressure10000 psi (689 bar)
Max. Operating Temperature750°F (399°C)
Manifold Material316 SST/316L SST
Packing MaterialPTFE, Graphite-based
Process Connection1/2″ -14 NPT female
Orientation: Parallel with transmitter
Certifications/ApprovalsCleaning for special services, sour gas (meets NACE MR 0175/ISO 15156, MR0103), see full specs for complete list of certifications
WarrantyUp to 5-year limited warranty
Ultrasonic
Rosemount™ JuniorSonic 3412 Two-Path Gas Ultrasonic Flow Meter
Ideal for allocation and check metering, the fully-redundant Rosemount JuniorSonic™ 3412 Two-Path Gas Ultrasonic Flow Meter combines a dual-bounce path design with powerful 3410 Series Electronics to ensure a superior non-fiscal measurement solution. This cost-effective meter is wet gas tolerant and features rugged Rosemount T-21 Transducers that are engineered for wet, rich and/or dirty gas applications for reliable, long-term performance. Innovative MeterLink™ Software ensures operators have easy access to the diagnostics generated by the meter for real-time detection of flow disturbances.
Specifications
Line SizesDN100 to DN900 (4-in to 36-in)
Fluid TypeGas
Accuracy±0.2% of reading with calibration (±1.5% of actual flow volume without calibration)
Repeatability±0.1% of reading for 5 to 100 ft/s (1.5 to 30.5 m/s)
VelocityRated up to 100 ft/s (30 m/s) with over-range performance exceeding 125 fps (38 m/s) on some sizes
Operating Temperature RangeT-21 Transducers: -20°C to +100°C (-4°F to +212°F)
T-41 Transducers: -50°C to +100°C (-58°F to +212°F)
Electronics: -40°C to +60°C (-40°F to +140°F
Operating Pressure RangeT-21 Tranducers: 1034 to 27,579 kPa (150 to 4000 psig)
T-41 Transducers: 1034 to 27,579 kPa (150 to 4000 psig)
MaterialsCarbon steel and stainless steel
Rosemount™ 3812 Two-Path Liquid Ultrasonic Flow Meter
Ideal for check metering and allocation, the economical Rosemount 3812 Two-Path Liquid Ultrasonic Flow Meter features two mid-radius, parallel-plane measurement paths that minimize measurement uncertainty caused by disturbed flow profiles. The meter is equipped with ultra-fast Rosemount 3810 Series Electronics that further enhance measurement stability and accuracy by minimizing sensitivity to changes in the flow profile, solids and/or entrained air. The intuitive operator interface within MeterLink™ Software helps operators identify costly flow disturbances and meter performance issues in real time to improve measurement and maintenance practices.
Specifications
Line SizesDN100 to DN900 (4-in to 36-in)
Fluid TypeLiquid
Linearity±0.3% of measured value over a 1.2 to 12.2 m/s (4 to 40 ft/s) range
Repeatability±0.10% of measured value
Velocity1.2 to 12.2 m/s (4 to 40 ft/s) with an extended range of 0.3 to 14.6 m/s (1 to 48 ft/s)
Operating Temperature RangeTransducers: -50°C to +100°C (-58°F to +212°F) or optional -50°C to +150°C (-58°F to +302°F)
Electronics: -40°C to +60°C (-40°F to +140°F)
Operating Pressure Range0 to 155 Bar (0 to 2,250 psig)
MaterialsCarbon steel and stainless steel
CalibrationConducted in Emerson’s ISO 17025 certified flow calibration laboratory
Rosemount™ 3810 Series Electronics for Liquid Ultrasonic Flow Meters
Compatible with all Rosemount 3810 Series Liquid Ultrasonic Flow Meters, next-generation Rosemount 3810 Series Electronics provide superior low-flow accuracy and linearity throughout the calibrated flow range for reliable, long-term performance. This powerful electronics platform reduces measurement uncertainty by rapidly processing ultrasonic flow data to ensure changing flow dynamics are communicated in a matter of seconds. In addition, the streamlined electronics design has fewer parts to simplify installation and reduce overall maintenance time and costs.
Specifications
Power10.4 VDC to 36 VDC
8 watts typical; 15 watts maximum
Operating Temperature Range-40°C to +60°C (-40°F to +140°F)
Operating Relative HumidityUp to 95% non-condensing
Storage Temperature-40°C to +85°C (-40°F to +185°F)
Mount OptionsIntegral mount (standard)
Remote mount (optional) with 4.6 m (15 ft) cable; required for process temperature above +60°C (+140°F)
MaterialsAluminum and stainless steel
Rosemount™ 3417 4+4 Dual-Configuration Gas Ultrasonic Flow Meter
Achieve the ultimate in fiscal measurement verification and validation with the fully-redundant Rosemount 3417 4+4 Ultrasonic Flow Meter that delivers the power of two field-proven Rosemount four-path, British Gas-design ultrasonic meters (certified to OIML R137 1&:2 Accuracy Class 0.5) in a single body. This advanced meter generates two independent measurements on one meter run for superior measurement accuracy, reliability and uptime. Innovative MeterLink™ Software provides immediate access to a wealth of predictive diagnostics generated by the meter’s ultra-fast 3410 Series Electronics for real-time detection of flow disturbances to reduce measurement uncertainty and simplify maintenance.
Specifications
Line SizesDN200 to DN1050 (8-in to 42-in) with British Gas (BG) orientation
Fluid TypeGas
Accuracy±0.1% of reading relative over entire flow calibration range
Repeatability±0.05% of reading for 5 to 100 ft/s (1.5 to 30.5 m/s)
VelocityRated up to 100 ft/s (30 m/s) with over-range performance exceeding 125 ft/s (38 m/s) on some sizes
Operating Temperature RangeT-21 Transducers: -20°C to +100°C (-4°F to +212°F)
T-22 Transducers: -50°C to +100°C (-58°F to +212°F)
T-200 Transducers: –50°C to 125°C (–58°F to +257°F)
Operating Pressure RangeT-21/T-22 Transducers: 689 to 27,579 kPag (100 to 4,000 psig)
T-21/T-22 Transducers: 345 kPag (50 psig) minimum operating pressure available with reduced Qmax
T-22 Transducers: 0 to 689 kPag (0 to 100 psig) isolated transducer mou
T-200 Transducers (up to 12” line size): 103 to 25,855 kPag (15 to 3,750 psig)
For line sizes >12″, minimum pressure increases based on line size
MaterialsCarbon steel and stainless steel
Multiphase
Roxar 2600 Multiphase Flow Meters
The Roxar 2600 Multiphase Flow Meters (MPFM) accurately characterize flow regimes and provide critical information on a well’s production capabilities. Built on a scalable technology platform, the advanced meter’s signal processing and field electronics provide sensitive measurements and a comprehensive mapping of flow. Employ this modular meter to improve production optimization, flow assurance and well testing, while meeting all field conditions and cost requirements.
Specifications
Operating range0-100% water in liquid ratio (WLR)
0-100% gas volume fraction (GVF)
InstallationVertical upwards flow
Sensor technologyDP 26 – Multi electrode, dual plane
Roxar Zector technology
Communication portRS-485/Ethernet
CertificationsATEX, IECEx, CSA C/US and EAC
Roxar Subsea Wetgas Meters
Roxar Subsea Wetgas meters provide highly accurate water, gas and condensate flow rates, reducing risk and improving flow assurance. The advanced meters deliver unparalleled water sensitivity, accuracy and rapid response for reliable production measurement.These include the industry’s first built-in salinity-measurement system, which provides information vital to protecting subsea well and pipeline integrity and supporting metering/allocation strategies in gas and gas condensate fields.
Specifications
Operating range90-100% GVF
Velocity range5 to 40 m/s
Temperature rangeUp to 150°C (302°F)
Water fraction measurementUncertainty: GVF > 98%: ±0.1 abs. vol.%
Uncertainty: GVF < 98%: ±0.2 abs. vol.%
Sensitivity< 0.0002 abs. vol.%
Communication protocolModbus RTU, Modbus TCP, Ethernet, CanBus
Roxar Multiphase Salinity System
The Roxar Multiphase Salinity System provides sensitive and real-time measurements of the conductivity and salinity of produced water in multiphase production wells. Together with the Roxar Multiphase Meter, this enables operators to obtain saline independent multiphase measurements, take immediate remedial action to improve flow assurance (optimizing corrosion, erosion and scale inhibitors), minimize water coning, and maximize oil & gas production.
Specifications
Uncertainty±0.5 abs Siemens/meter conductivity
±0.5 abs % Salinity (NaCl)
Operating rangeWTR(1) – 100% Water Liquid Ratio (WLR)
0 – 80%(2) Gas Volume Fraction (GVF)
(1) Water transition point
(2) Operating range can be extended towards 90% GVF dependent on operating pressure and flow profile
Operating range(1) Water transition point(2) Operating range can be extended towards 90% GVF dependenton operating pressure and flow profile
Pressure5000 psi (345 bars)
Temperature-20 to +130 °C (-4 to +266 °F)
Meter sizes2” to 6”, other sizes available upon request
Sensor technologyMicrowave transmission sensor
Communication Ports:RS-485 x 2
Length750 mm
Turbine
Watercut
Rosemount™ 705 Wireless Totalizing Transmitter
Empower your turbine flow measurement with the Rosemount™ 705 Wireless Totalizing Transmitter. This transmitter is equipped with wireless technology that consistently delivers average flow rate and totalized volume measurements, even in remote and challenging environments. Ready-to-install, this wireless transmitter provides you with continuous and reliable pulse data from the field and delivers predictive diagnostics data to indicate instrument health and support timely maintenance.
Specifications
Update Rate1 second to 60 minutes, user selectable
Power SupplyReplaceable, intrinsically safe lithium-thionyl chloride power module with PBT polymer enclosure
Housing MaterialLow-copper aluminum, or stainless steel
Antenna TypeExternal (WK option) antenna: Maximum of 10mW (10 dBm) EIRP; Extended range, External (WM option) antenna: Maximum of 18 mW (12.5 dBm) EIRP; High Gain, Remote (WN option) antenna: Maximum of 40 mW (16 dBm) EIRP; Remote (WJ option) antenna: Maximum of 17 mW (12.3 dBm) EIRP
Display/InterfaceOptional
Roxar™ Watercut Meters
Inline, field–mounted Roxar Watercut Meters use sensitive, microwave–resonance technology to accurately measure the permittivity of oil/water mixtures in real– time. The full–bore meters improve wellhead efficiencies, separation processes, custody transfers and fiscal reporting, and can be easily adjusted for salinity and changing dry–oil densities.
Specifications
Inline Low Cut Range0-15%
Inline High Cut Range1-50%
Effect of density variations0.027% water per 1 kg/m3
Effect of pressure variations0.0025% water per 1 bar
Measurement TypeMicrowave Resonance Technology
Connection TypeDigital I/O 1200m (RS 485)